Issue with Data bus Buffering

eZ80 for RC2014™ and compatible backplanes

An eZ80 CPU Module that works within the RC2014™ ecosystem

15 Jun 2024


As mentioned in a previous post HBIOS booted on the eZ80, there was an issue with the Memory Module - where it would only work if I used the 74HC670 chips (instead of the similar 74HCT670). I think the problem for this might have to do with a problem I had discovered with the way I was buffering the Data lines (D0-D7) between the eZ80 and the backplane.

I noticed that I was ‘disabling’ the buffer chip when the eZ80’s RD or WR was not active. This is certainly not right.

The memory module is a bank memory system. It uses the 74HCx670 chips to manage the banking, allowing a normal Z80 to address more than 64K. The 74HCx670 ‘latch’ or store a specific higher address value for each of the 4 banks within the 64K range. To assign a specific value, the processor needs to do an I/O write to the 670’s.

As the 74HCx670 will latch the data lines as the WR signal goes from low to high, it would be trying to read data lines that are at the same time, transitioning to a high-impedance state (floating in-active). Thus preventing the correct transfer of the data.

I have fix this, so that the buffered data lines are stable after the WR goes high, as required by the eZ80 timing.

I have yet to re-test the Memory Module, using the 74HCT670 variants - Will try and confirm this soon.